title: Data Collection Module (DCM) | PlantStar MES
description: The PlantStar DCM can collect data from any machine interface, including OPC-UA, MODBUS, EUROMAP63, and can be used with older machines or equipment.
image: https://plantstar.com/hubfs/IMG_8496.png
---

[![syscon-plantstar-1](https://plantstar.com/hubfs/syscon-plantstar-1.png) ](https://plantstar.com?hsLang=en)

- [MES Solutions](https://plantstar.com/mes-solutions) 
    - [Production Monitoring](https://plantstar.com/production-monitoring)
    - [Process Monitoring](https://plantstar.com/process-monitoring)
    - [Panorama vs. PlantStar 4.0](https://plantstar.com/panorama-vs-plantstar)
    - [MES Images](https://plantstar.com/en-us/mes-images)
    - [Manufacturing Dashboards](https://plantstar.com/manufacturing-dashboards)
    - [MES 101](https://plantstar.com/manufacturing-execution-systems-mes-101)
    - [Frequently Asked Questions](https://plantstar.com/frequently-asked-questions)
- [Hardware](https://plantstar.com/hardware) 
    - [HMI](https://plantstar.com/human-machine-interface)
    - [PlantStar All-in-One HMI](https://plantstar.com/all-in-one-hmi)
    - [Mini-HMI](https://plantstar.com/mini-human-machine-interface-hmi)
    - [HMI Pedestal](https://plantstar.com/hmi-pedestal)
    - [DCM](https://plantstar.com/data-collection-module)
    - [PLC Data Collection Module (DCM)](https://plantstar.com/plc-data-collection-module)
    - [APU](https://plantstar.com/application-processing-unit)
    - [PlantStar Dashboard Displays](https://plantstar.com/plantstar-dashboard-displays)
- [Support](https://plantstar.com/support)
- [Who We Serve](https://plantstar.com/plantstar/who-we-serve) 
    - [Case Studies](https://plantstar.com/case-studies)
- [About Us](https://plantstar.com/about)
- [Blog](https://plantstar.com/blog)
- [Contact Us](https://plantstar.com/contact)

[English](https://plantstar.com/data-collection-module#) [简体中文](https://plantstar.com/data-collection-module#) [繁體中文](https://plantstar.com/data-collection-module#) [Spanish](https://plantstar.com/data-collection-module#)

# Data Collection Module (DCM)

The PlantStar Data Collection Modules provide unmatched shop floor redundancy with the capability to gather data from any machine via direct digital, analog, or serial interfaces. The newest PlantStar Data Collection Module (DCM) boasts 9 available I/O slots which can include a combination of up to 48 digital inputs, 24 digital outputs and up to 36 analog inputs. Multiple RS-232 and RS-485 intefaces can also be configured if needed. With PlantStar's Manufacturing Execution System, if your APU is down or you experience network issues, the Data Collection Module can continue to run previously scheduled jobs without interruption, then sync back up with no loss of data. Additionally, our newest Data Collection Modules can handle cycle times as low as 10ms for extremely high speed data collection.

[Download Data Sheet](https://plantstar.com/hubfs/syscon-dcm-data-sheet-2023.pdf?hsLang=en)

**

## Key Functions

- Industrial strength network edge device for high performance data collection
- Collects real-time production and process data from all types of production equipment
- Connect up to 48 machines per DCM
- Configurable with up to 48 digital inputs, 24 digital outputs and 36 analog inputs
- Integral wire management system for improved serviceability
- 24V power available for external or internal signal isolation relays
- Internal DIN rail mount for additional expansion flexibility
- Multiple mounting configurations; easy access front panel 
- Internal or external power wiring and on/off switch for improved security
- 24x7 remote support and management

**

## Specifications

- Intel J1900 CPU
- 8 GB RAM
- 2x 1 Gbps ethernet ports
- Debian Linux operating system 
- PlantStar Remote IO processor with high speed USB interface
- Expandable via built-in 9 slot SPI bus backplane
- Digital I/O expansion cards with 16 input/8 output (requires 3 slots each)
- Analog I/O expansion cards with 8 inputs (requires 1 slot each)
- Multiple RS-232 and RS-485 interfaces available
- 13.4" x 16.9" x 6.25"

![IMG_5383-1](https://plantstar.com/hs-fs/hubfs/2024%20Summer%20Tristan%20Photos/DCM%20rotation%20images/IMG_5383-1.png?length=800&name=IMG_5383-1.png)

![IMG_8486](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8486.png?length=800&name=IMG_8486.png)

![IMG_8489](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8489.png?length=800&name=IMG_8489.png)

![IMG_8490](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8490.png?length=800&name=IMG_8490.png)

![IMG_8492](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8492.png?length=800&name=IMG_8492.png)

![IMG_8493](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8493.png?length=800&name=IMG_8493.png)

![IMG_8494](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8494.png?length=800&name=IMG_8494.png)

![IMG_8487](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8487.png?length=800&name=IMG_8487.png)

![IMG_8498](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8498.png?length=800&name=IMG_8498.png)

![IMG_5383-1](https://plantstar.com/hs-fs/hubfs/2024%20Summer%20Tristan%20Photos/DCM%20rotation%20images/IMG_5383-1.png?length=800&name=IMG_5383-1.png)

![IMG_8486](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8486.png?length=800&name=IMG_8486.png)

![IMG_8489](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8489.png?length=800&name=IMG_8489.png)

![IMG_8490](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8490.png?length=800&name=IMG_8490.png)

![IMG_8492](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8492.png?length=800&name=IMG_8492.png)

![IMG_8493](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8493.png?length=800&name=IMG_8493.png)

![IMG_8494](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8494.png?length=800&name=IMG_8494.png)

![IMG_8487](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8487.png?length=800&name=IMG_8487.png)

![IMG_8498](https://plantstar.com/hs-fs/hubfs/2025%20Tristan%20PlantStar%20photos/New%20DCM%20(gray)/IMG_8498.png?length=800&name=IMG_8498.png)

✕

**

✕

**

## Additional Solutions

![just-in-time-manufacturing-inventory](https://plantstar.com/hubfs/just-in-time-manufacturing-inventory.jpg)

### [ Software ](https://plantstar.com/process-monitoring?hsLang=en)

With more than 50 years of industry experience, PlantStar has vast experience developing MES software. Our latest version, PlantStar 4.0, offers industry-leading features that allow companies to manage their processes more efficiently.

View Our Software

![stock image 17](https://plantstar.com/hubfs/stock%20images/stock%20image%2017.jpeg)

### [ Support Services ](https://plantstar.com/support?hsLang=en)

Are you struggling to get your machines running after unexpected downtime or need help installing equipment? We’re here to provide support and help you keep your business running smoothly.

View Support Services

## Want a firsthand look at how PlantStar works?

Contact us today to schedule a demo!

[![syscon-plantstar-1](https://plantstar.com/hs-fs/hubfs/syscon-plantstar-1.png?width=300&height=52&name=syscon-plantstar-1.png "syscon-plantstar-1")](https://plantstar.com/?hsLang=en)

Copyright © 2026 syscon-intl.com All Rights Reserved

- [MES Solutions](https://plantstar.com/mes-solutions)
- [Hardware](https://plantstar.com/hardware)
- [Support](https://plantstar.com/support)
- [Knowledge Center](https://kb.syscon-intl.com/knowledge)
- [FAQs](https://plantstar.com/frequently-asked-questions)

- [Who We Serve](https://plantstar.com/plantstar/who-we-serve)
- [About Us](https://plantstar.com/about)
- [Blog](https://plantstar.com/blog)
- [Contact](https://plantstar.com/contact)

1108 High St. South Bend, Indiana 46601

[+1 574-232-3900](tel:15742323900)

```json
{
  "@context" : "https://schema.org/",
  "@type" : "Product",
  "brand" : {
    "@type" : "Brand",
    "name" : "SYSCON PlantStar"
  },
  "description" : "The newest PlantStar Data Collection Module (DCM) boasts 9 available I/O slots which can include a combination of up to 48 digital inputs, 24 digital outputs and up to 36 analog inputs. Multiple RS-232 and RS-485 interfaces can also be configured if needed.",
  "image" : "https://plantstar.com/hubfs/2024%20Summer%20Tristan%20Photos-%20PlantStar/DCM%20rotation%20images/IMG_5398-1-1.png",
  "name" : "Data Collection Module (DCM)"
}
```